CCare Note
Menu

Echocardiography · Article 1

Reading an echocardiography report: EF, wall motion and valves in nursing observation

Use synthetic images to connect EF, wall motion and valve findings with what to observe. Keep the report, current observations and questions separate. All images and videos are synthetic and cannot be used for diagnosis.

All images and videos in this article are synthetic educational images, not patient recordings. Shapes and movement have been simplified for learning. They cannot be used for diagnosis or quantitative assessment.

This article is for nurses and nursing students. You do not need to memorize every abbreviation on an echo report at once. Use the viewing points alongside the synthetic images to separate “what the report says,” “what I have observed now” and “what I need to ask.”

The aim is not to make diagnostic or treatment decisions independently. In practice, prioritize the patient’s condition, institutional procedures and the physician’s instructions. The original article is based in Japan and cites Japanese guidelines; references to institutional practice describe that context, not a universal protocol.

1. Check when the examination was performed and why

Start with the examination date, its purpose and the date of the previous examination used for comparison. Next, read the overall impression, the summary of the examination as a whole. You can retain unfamiliar abbreviations exactly as written in your questions.

  • Check the dates. Keep the current and previous results separate.
  • Keep the original wording. Do not fill in numbers, units, locations or severity by guessing.
  • Add your current observations. Do not merge findings at the time of the examination with the patient’s condition now.

Avoid copying a previous finding as though it had been newly confirmed in the current examination. Record the measurement method and any statement such as “difficult to assess” alongside the value. Quantitative assessment of left ventricular ejection fraction (LVEF, the proportion by which left ventricular volume decreases) is subject to measurement error, so values need careful interpretation. [G1: Chapter 3, section 2.2.1, p.34]

What is on the report, or what you have checkedHow to record it
The item is not documented“Not documented”
The report says “difficult to assess”Keep “difficult to assess” as written
You have not yet reviewed the material yourself“Not yet checked by me”

This distinction is an editorial suggestion for this article. It helps prevent an empty field from being interpreted as “no abnormality.”

2. Understanding the views: find the chambers and valves first

A4C: find the four chambers

A view shows the heart as if it had been cut along a particular plane. The apical four-chamber view (A4C) looks at the four chambers from the apex, the pointed end of the heart. The atria receive blood; the ventricles pump it out.

Figure 1. The four chambers and valves in A4C. The right heart is on the left of the screen, and the left heart is on the right. Synthetic educational image. Not a patient recording. Not for diagnosis.

Figure 1. The four chambers and valves in A4C. The right heart is on the left of the screen, and the left heart is on the right. Synthetic educational image. Not a patient recording. Not for diagnosis.

What to look for

  • In this image, the right ventricle (RV) is at the upper left and the right atrium (RA) at the lower left. The left ventricle (LV) is at the upper right and the left atrium (LA) at the lower right. Distinguish screen directions from the right and left sides of the heart.
  • The tricuspid valve (TV) lies between the RA and RV; the mitral valve (MV) lies between the LA and LV. The interventricular septum (IVS) separates the two ventricles.
  • The apex is toward the top; the atria lie below the valves. Actual displays vary with the equipment and settings. Check the view name and labels instead of assuming the orientation.

PLAX: follow the LV, mitral valve and aortic valve

The parasternal long-axis view (PLAX) looks along the length of the LV from beside the sternum. It shows the same heart as A4C, cut in a different direction.

Figure 2. Relationships in PLAX: follow the LV, LA, mitral valve and aortic valve. Synthetic educational image. Not a patient recording. Not for diagnosis.

Figure 2. Relationships in PLAX: follow the LV, LA, mitral valve and aortic valve. Synthetic educational image. Not a patient recording. Not for diagnosis.

What to look for

  • The large chamber toward the left of the screen is the LV; the chamber at the lower right is the LA. Find the mitral valve between them.
  • The aortic valve (AV) is at the outlet from the LV toward the aorta in the upper right of the screen. To distinguish it from the mitral valve, identify the chambers or vessel on either side.
  • The RV side is visible above the LV, with the interventricular septum between them. This synthetic image simplifies shapes and spatial relationships.

Connecting this with the report: retain the original valve name when recording a valve finding. Do not supply a finding or valve name simply because something resembles the illustration.

PSAX: look at the ring-shaped LV and surrounding wall

The parasternal short-axis view (PSAX) cuts across the LV from beside the sternum. This figure shows the level of the papillary muscles. These muscles support the valves through the chordae tendineae, the cord-like tissues connecting the valves to the muscles.

Figure 3. PSAX at the papillary muscle level. Look at the wall surrounding the LV and the RV on the left of the screen. Synthetic educational image. Not a patient recording. Not for diagnosis.

Figure 3. PSAX at the papillary muscle level. Look at the wall surrounding the LV and the RV on the left of the screen. Synthetic educational image. Not a patient recording. Not for diagnosis.

What to look for

  • The dark area enclosed by the ring-shaped wall in the center is the LV cavity, the inside of the chamber.
  • The RV appears to the left of the LV on the screen. Find the interventricular septum between the two ventricles.
  • The two bright areas toward the lower part of the cavity are the papillary muscles represented in this figure. The structures visible change with the level of the imaging plane.

We will use this PSAX view again to compare wall motion. First establish which chamber you are looking at, then follow its wall.

3. EF: look at the change in LV volume

The left ventricle is the chamber that pumps blood to the body. EF stands for ejection fraction; here it means left ventricular ejection fraction (LVEF). If a report says EF, confirm which value it refers to.

End-diastole is when LV volume is largest, just before contraction. End-systole is when LV volume is smallest. EF expresses how much the LV volume decreases during contraction as a proportion of its end-diastolic volume.

EF = (end-diastolic volume − end-systolic volume) ÷ end-diastolic volume × 100 (%). Do not calculate it from the area of this synthetic image. EF is defined using volumes. EDV means end-diastolic volume; ESV means end-systolic volume. The source formula is EF = (EDV − ESV) / EDV; this article adds ×100 to express the result as a percentage. [ASE 2015, simultaneous EHJ-CVI publication, section 2.2 “EF”]

Actual volume-based measurement methods include the modified Simpson method, which estimates volume by tracing the LV contours. See G1 for measurement methods and assessment conditions. [G1: Chapter 3, section 2.2.1, p.34]

Do not determine heart failure from EF alone

EF is a central measure of LV systolic function, but it is affected by loading conditions, including the amount of blood entering the heart and the load against which it pumps. Assessment combines several measures. [G1: Chapter 3, section 2.1, pp.33–34]

Diagnosis of heart failure combines symptoms, history, physical findings and investigations. EF alone does not establish whether heart failure is present or absent. [G4: Chapter 2, section 1.1, p.19; Chapter 4, section 1, p.29]

This article does not give normal EF values or severity cutoffs. Retain the value, unit, measurement method and overall impression from the report, and ask the responsible clinician about their interpretation.

Video 1: watch the LV become smaller and expand again

Video 1 poster. One frame from a synthetic A4C video showing LV contraction and relaxation. Synthetic educational image. Not a patient recording. Not for diagnosis.

Video 1 poster. One frame from a synthetic A4C video showing LV contraction and relaxation. Synthetic educational image. Not a patient recording. Not for diagnosis.

What to look for: follow the LV cavity on the right of the screen as it becomes smaller during systole and expands again during diastole. The poster is a frame partway through contraction, not a pair of end-diastolic and end-systolic images. Compare the larger and smaller phases within the video.

This movement is a starting point for thinking about volume changes. Do not calculate EF from image area or the proportion of shrinkage. The video does not reproduce actual three-dimensional volumes, blood flow or the detailed phases of the cardiac cycle.

Included file: `/en/articles/echo-report-nursing-observation/loop-a4c-ef.mp4`

Open short GIF (first 3 seconds, 640 pixels wide, 10 fps, looping)

In a PDF, only the poster is displayed. Use the included MP4 or GIF to see the movement.

4. Wall motion: which part moves, and how?

Wall motion means movement of the heart’s walls. Regional LV wall motion abnormalities require assessment by location. [G1: Chapter 3, section 2.3, p.34]

Comparison 1: inward contraction around the whole circumference

Figure 4. PSAX comparison at end-systole. The dashed line marks the end-diastolic cavity contour. Synthetic educational image. Not a patient recording. Not for diagnosis.

Figure 4. PSAX comparison at end-systole. The dashed line marks the end-diastolic cavity contour. Synthetic educational image. Not a patient recording. Not for diagnosis.

What to look for: compare the dashed ring with the current edge of the cavity. In this example, the wall moves inward around the whole circumference, making the cavity smaller. Follow the bright wall all the way around and identify where it has moved inward.

Figure 5 uses the same orientation and the same intended end-systolic phase. Compare the change from the dashed line to the cavity edge. These schematics cannot determine whether a clinical finding is normal or abnormal.

Comparison 2: less movement in one region

Figure 5. Compared with Figure 4, inward movement is reduced in the orange anterior-wall region. Synthetic educational image. Not a patient recording. Not for diagnosis.

Figure 5. Compared with Figure 4, inward movement is reduced in the orange anterior-wall region. Synthetic educational image. Not a patient recording. Not for diagnosis.

What to look for

  • In the orange region at the top of the screen, the change from the dashed line to the cavity edge is drawn smaller than in the other walls.
  • Other walls move inward. Distinguish “less movement in one region” from “no movement throughout.”
  • “Anterior-wall region” describes the arrangement within this synthetic image. Identifying an anatomical region in practice requires checking the view’s orientation and other information.

Connecting this with the report: record the location together with the wording used to describe its movement. If you do not understand a location name, retain it and ask about it. Do not infer a cause, diagnosis or coronary artery territory from the image or from the phrase “poor movement” alone.

Video 2: follow the same region through one beat

Video 2 poster. One frame for comparing the orange region with the other walls. Synthetic educational image. Not a patient recording. Not for diagnosis.

Video 2 poster. One frame for comparing the orange region with the other walls. Synthetic educational image. Not a patient recording. Not for diagnosis.

What to look for: keep track of the orange region as the cavity expands and becomes smaller. Then look at the other walls and compare their inward movement. The dashed line marks the end-diastolic cavity contour.

Wall movement and changes in thickness are simplified for education. Arrow lengths and the extent of the colored region cannot indicate the severity of a lesion. In actual assessment, also note any regions that could not be assessed so you can ask the responsible clinician about them.

Included file: `/en/articles/echo-report-nursing-observation/loop-psax-wall-hypokinesis.mp4`

Open short GIF (first 3 seconds, 640 pixels wide, 10 fps, looping)

In a PDF, only the poster is displayed. Use the included MP4 or GIF to see the movement.

5. Valves and Doppler: consider timing and flow direction together

Valves help keep blood flowing in one direction. Reports may name the aortic, mitral, tricuspid and pulmonary valves. Stenosis means narrowing of the opening. Regurgitation means blood flows backward because the valve does not close sufficiently during the phase when it should be closed.

Color Doppler uses color to display information such as the direction of blood flow assessed by ultrasound. In these synthetic illustrations, flow toward the probe, which sends and receives ultrasound, is predominantly red; flow away from it is predominantly blue. The colors do not indicate oxygen content or distinguish arteries from veins.

Normal inflow: through the open mitral valve into the LV during diastole

Figure 6. Diastolic mitral inflow, from the LA toward the LV. Synthetic educational image. Not a patient recording. Not for diagnosis.

Figure 6. Diastolic mitral inflow, from the LA toward the LV. Synthetic educational image. Not a patient recording. Not for diagnosis.

What to look for: check “Diastole” and “MV: open” at the lower left. Follow the predominantly red flow from the LA through the open mitral valve into the LV toward the top of the screen. The presence of color alone does not mean regurgitation.

Regurgitation: leakage into the LA during systole, when the mitral valve should close

Mitral regurgitation (MR) is backward flow from the LV into the LA during ventricular contraction, when the mitral valve should be closed. This example shows a small gap remaining at the point where the leaflets attempt to meet.

Figure 7. Systolic mitral regurgitation. Leakage toward the LA is shown during the phase when the valve should be closed. Synthetic educational image. Not a patient recording. Not for diagnosis.

Figure 7. Systolic mitral regurgitation. Leakage toward the LA is shown during the phase when the valve should be closed. Synthetic educational image. Not a patient recording. Not for diagnosis.

What to look for: check “Systole” and “MV: closing; small gap” at the lower left. The colored region extending from the valve down into the LA represents regurgitation schematically. Its timing and direction differ from the diastolic inflow in Figure 6.

The predominantly blue pattern with red mixed in is a simplified depiction of velocities beyond the display range wrapping into another color. A mixture of red and blue alone does not establish direction or severity. Consider valve and chamber positions together with timing.

Connecting this with the report: distinguish the valve name, the description of stenosis or regurgitation, and the stated severity. An integrated assessment also considers chamber size, cardiac function, blood flow and pressure conditions. [G5: Chapter 1, section 2, p.13]

In PLAX, check that the leakage also goes into the LA

Now look at the mitral regurgitation shown in A4C from the PLAX view. First recall the positions of the LV, LA and mitral valve in Figure 2.

Figure 8. Systolic mitral regurgitation in PLAX. The illustration shows leakage from the LV through the mitral valve into the LA. Synthetic educational image. Not a patient recording. Not for diagnosis.

Figure 8. Systolic mitral regurgitation in PLAX. The illustration shows leakage from the LV through the mitral valve into the LA. Synthetic educational image. Not a patient recording. Not for diagnosis.

What to look for

  • Find the mitral valve between the LV on the left of the screen and the LA at the lower right.
  • The colored region extends from the label “MV (should be closed)” into the LA at the lower right. This is also systolic leakage.
  • Even when the orientation changes, ask: which valve, at what time, and in which direction? Do not identify a valve by color alone.

The extent of the color, color-bar numbers and size of the gap are educational representations. They cannot be used to measure velocity or regurgitation severity. This article gives no diagnostic or severity thresholds for stenosis or regurgitation. [G5]

Video 3: distinguish diastolic inflow from systolic regurgitation

Video 3 poster. During systole, leakage enters the LA through the remaining gap in the mitral valve, which should be closed. Synthetic educational image. Not a patient recording. Not for diagnosis.

Video 3 poster. During systole, leakage enters the LA through the remaining gap in the mitral valve, which should be closed. Synthetic educational image. Not a patient recording. Not for diagnosis.

What to look for: in the video, the mitral valve opens during diastole, allowing inflow from LA to LV. During systole, when it should be closed, blood regurgitates from LV to LA through the remaining gap. Follow the phase display at the lower left together with the valve shape and the side on which color appears.

This example of “systolic regurgitation” concerns the mitral valve. The phase when a valve should be closed differs between valves. It does not mean regurgitation through every valve occurs during systole. Detailed timing and flow are simplified. [G5]

Included file: `/en/articles/echo-report-nursing-observation/loop-a4c-color-mr.mp4`

Open short GIF (first 3 seconds, 640 pixels wide, 10 fps, looping)

In a PDF, only the poster is displayed. Use the included MP4 or GIF to see the movement.

6. Connect the report with current observations

Keep findings from the examination and current observations in separate fields. G4 describes observing physical findings in heart failure over time. The following reporting note is an editorial suggestion informed by that approach. [G4: Chapter 4, section 2.2.1, p.32]

FieldWhat to enter
Purpose of the discussionWhat needs clarification now: ___
Dates of the materialCurrent examination: ___ / previous examination for comparison: ___
What the report saysOverall impression: ___ / EF value, unit and method: ___
Location and wordingWall motion location and exact wording: ___ / valve, stenosis or regurgitation, severity: ___
Current observationsTime: ___ / what the patient reports: ___ / breathing, circulation and other observations, with measurement conditions: ___
Course and actionsChanges from the usual condition: ___ / actions and instructions, with times: ___
QuestionsItems not documented, difficult to assess or not yet checked: ___ / are the conditions comparable? ___

Quick question 1: “An EF value is documented, so there is no need to report the patient’s breathing or what they are experiencing.” Is this correct?

Answer: no. EF is one measure. Assessment combines examination findings with current symptoms and observations. [G1, G4]

Quick question 2: the valve field is blank. Can you write “no valve abnormality”?

Answer: no. Record “not documented.” If it says “difficult to assess,” retain that wording. Check the overall impression as well and ask about the points that need clarification.

Quick question 3: the previous and current EF values differ. Can you immediately hand this over as “deterioration”?

Answer: separate the numerical difference from a judgment of deterioration. Record the dates, values, measurement methods and assessment conditions, and ask the responsible clinician whether the results can be compared. EF is affected by loading conditions and measurement error. [G1: pp.33–34]

When the patient’s condition changes, follow institutional emergency procedures and the physician’s instructions for responding and calling for help. Do not wait to interpret the report or complete the note. This is not a form for entering real patient information into an external learning service.

References and sources

G1: Japanese Circulation Society et al. 2021 Guideline on the Clinical Application of Echocardiography (Japanese-language guideline; published March 27, 2021; updated August 4, 2021). https://www.j-circ.or.jp/cms/wp-content/uploads/2021/03/JCS2021_Ohte.pdf (Date checked in the Japanese source: 2026-11-10.)

Relevant printed pages: Chapter 3, section 2.1, pp.33–34 (the role of LVEF, load dependence and combining several measures); section 2.2.1, p.34 (volume-based measurement and measurement error); section 2.3, p.34 (regional wall motion assessment). The schematics and videos were created for this article and do not reproduce the guideline’s figures.

ASE 2015: Lang RM et al. Recommendations for Cardiac Chamber Quantification by Echocardiography in Adults: An Update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. JASE 2015;28:1–39.e14. doi:10.1016/j.echo.2014.10.003. https://doi.org/10.1016/j.echo.2014.10.003 . The EF formula appears in section 2.2 “EF” of the simultaneous EHJ-CVI publication (2015;16:233–271, doi:10.1093/ehjci/jev014): EF = (EDV − ESV) / EDV. This article multiplies by 100 to express it as a percentage. (Date checked in the Japanese source: 2026-11-10.)

SourceCorresponding content in this article
ASE 2015 (Lang RM et al.), simultaneous EHJ-CVI publication, doi:10.1093/ehjci/jev014, section 2.2 “EF”EF = (EDV − ESV) / EDV, multiplied by 100 here for a percentage
G1, Chapter 3, section 2.2.1, p.34Volume-based measurement methods and measurement error
G4, Chapter 2, section 1.1, p.19; Chapter 4, section 1, p.29 and section 2.2.1, p.32Heart failure diagnosis and observation over time
G5, Chapter 1, section 2, p.13Integrated assessment of valve disease, including regurgitation and stenosis

G4: Japanese Circulation Society and Japanese Heart Failure Society. 2025 Guideline on Diagnosis and Treatment of Heart Failure (Japanese-language guideline; published March 28, 2025; updated December 19, 2025). https://www.j-circ.or.jp/cms/wp-content/uploads/2025/03/JCS2025_Kato.pdf (Date checked in the Japanese source: 2026-11-10.)

Relevant printed pages: Chapter 2, section 1.1, p.19 (definition of heart failure); Chapter 4, section 1, p.29 (assessment combining symptoms, history, physical findings and investigations); section 2.2.1, p.32 (observing physical findings over time). This supports the explanation that EF alone does not establish the diagnosis; it is not presented as a recommendation for a nursing documentation format.

G5: Japanese Circulation Society et al. 2020 Guideline on the Management of Valvular Heart Disease (Japanese-language guideline; published March 13, 2020; updated October 16, 2020). https://www.j-circ.or.jp/cms/wp-content/uploads/2020/04/JCS2020_Izumi_Eishi.pdf (Date checked in the Japanese source: 2026-11-10.)

Relevant printed page: Chapter 1, section 2, p.13 (integrated assessment including regurgitation, stenosis, chamber size, cardiac function and hemodynamics). This provides the background for recording the valve name, stenosis or regurgitation, and severity separately. Treatment indications and numerical thresholds are outside this article’s scope.

The text, eight figures, three videos, three posters and reporting note were created and edited for this article. The images and videos are synthetic: the dark sector-shaped scan field, speckle, wall thickness and color Doppler patterns were generated procedurally. No pixels, contours, text or footage from real patient echocardiograms, user-supplied reference figures or third-party teaching materials were used. The English edition replaces the Japanese annotations and on-screen labels while preserving the synthetic anatomy and movement. Shapes and movement are simplified for education. This is a public learning resource, but it has not undergone medical supervision. Synthetic educational image. Not a patient recording. Not for diagnosis.

Continue learning

Echocardiography: learning guide

Explore all five cardiology topics