CCare Note
Menu

Arrhythmias · Article 1

When an arrhythmia alarm sounds: a first guide to observation, documentation and reporting

Check the patient first. Learn to separate what you observed from what you do not yet know, even when you cannot name the rhythm.

When an alarm sounds, it is tempting to look for the name of the rhythm first. Start by checking the patient. Even if you cannot name the rhythm, you can report what you have seen and distinguish it from what you do not yet know.

This learning article is for nurses and nursing students. In practice, prioritize the patient’s condition, your institution’s emergency procedures and the physician’s instructions. Do not delay calling for help to read a figure or finish a note. The original article is based in Japan and cites Japanese guidelines; its references to institutional procedures describe that context, not a universal protocol.

Start with these three points

  • Look at the patient. Check responsiveness, breathing and circulation, what the patient reports, and when the change occurred.
  • Separate the display from your observations. The alarm label is the device’s interpretation. Record the waveform features you can identify separately.
  • Connect what happened before and after. When did it start, and what is happening now? Report what you have done and what remains unconfirmed.

This sequence and the reporting format are editorial suggestions developed for this article. G2 describes the role of the history, physical findings and ECG. It is not cited as a nursing protocol for responding to alarms. [G2: Chapter 1, section 3, p.12]

Figure 1. Organizing information when an alarm sounds. Follow institutional procedures for urgent action; do not wait to finish a note. Original educational illustration. Not a patient ECG. Not for diagnosis.

Step 1: learn just three waveform names

An ECG records the heart’s electrical activity. The waveform alone does not tell you the blood pressure or how well blood is flowing through the body.

  • P wave: the wave representing atrial excitation. The atria are the upper chambers of the heart.
  • QRS complex: the group of waves representing ventricular excitation. The ventricles are the chambers that pump blood out.
  • T wave: the wave representing the ventricles’ electrical recovery.

“Excitation” here means an electrical change. Distinguish it from mechanical contraction and the pulse itself. See [E1] for a review of the basic terms.

All the schematic ECGs below are original educational illustrations. A 12-lead ECG views the same cardiac electrical activity from different directions. The left column contains I, II, III, aVR, aVL and aVF; the right contains V1–V6. These are not twelve copies of a single waveform.

Figure 2. Original educational 12-lead illustration. Use P, QRS and T in lead II to find these shapes within the full recording. Not a patient ECG. Not for diagnosis.

The calibration pulse in each schematic is 1 mV high and 0.2 seconds wide. The displayed scale is 25 mm/s and 10 mm/mV. Each small grid square represents 0.04 seconds horizontally and 0.1 mV vertically. Images are resized on screens and in PDFs: use the grid and stated scale, not a ruler on the displayed image.

Step 2: describe RR intervals as similar or different

The R wave is an upward deflection in the QRS complex. The RR interval is the time from one R wave to the next. Longer intervals mean a slower rate; shorter intervals mean a faster rate.

For a schematic with regular RR intervals, the approximate heart rate is “60 divided by RR in seconds.” In the figure below, RR is 0.80 seconds, so 60 ÷ 0.80 = 75 beats/min. For an irregular recording, do not treat one RR interval as representing the rate of the entire recording. State the interval of the recording you examined and the calculation method.

Figure 3. Original educational illustration. RR markers are placed in lead II within the full 12-lead recording. RR is 0.80 seconds in this example. Not a patient ECG. Not for diagnosis.

Quick question 1: look at all of Figure 3. With RR at 0.80 seconds, is the schematic heart rate A: 48 beats/min, or B: 75 beats/min?

Answer: B. 60 ÷ 0.80 = 75 beats/min. An RR interval of 1.25 seconds gives 48 beats/min. This calculation estimates heart rate; it does not determine safety or the need for treatment.

Step 3: compare five patterns

First look at the relationship between P waves and QRS complexes, then RR intervals and, where needed, PR intervals. The PR interval runs from the onset of the P wave to the onset of the QRS complex. It is not measured from the peak of P to the peak of R.

Figure 4. Comparison of five patterns. Use the full 12-lead figures that follow for waveform practice. Original educational illustration. Not a patient ECG. Not for diagnosis.

The basic sinus rhythm pattern

Sinus rhythm starts in the sinus node, the heart’s usual electrical starting point. The schematic below illustrates the basic pattern of normal sinus rhythm at 75 beats/min. In lead II, positive P waves of the same shape precede the QRS complexes, with a 1:1 P-to-QRS relationship. This is not a diagnostic reference guaranteeing that the entire ECG is normal.

Figure 5. Original educational illustration of the basic sinus rhythm pattern at 75 beats/min. Check the relationship between P and QRS. Not a patient ECG. Not for diagnosis.

Sinus bradycardia and sinus tachycardia

Bradycardia means a slow rate; tachycardia means a fast rate. The next two schematics change the rate while preserving the P-to-QRS relationship. The numbers are settings for the illustrations, not thresholds for emergency action or starting treatment.

Figure 6. Original educational illustration of sinus bradycardia at 48 beats/min, with RR at 1.25 seconds. Not a patient ECG. Not for diagnosis.

Figure 7. Original educational illustration of sinus tachycardia at 120 beats/min, with RR at 0.50 seconds. Not a patient ECG. Not for diagnosis.

Figure 7a. q02, 0–5 seconds: a real sinus tachycardia waveform. PTB-XL v1.0.3, record 00108. Wagner et al.; PhysioNet; CC BY 4.0. 25 mm/s; 10 mm/mV. Japanese title and footer cropped; waveform area preserved.

Check a real recording: sinus tachycardia. RR intervals across the first three beats are approximately 0.48 seconds (0.482–0.510 seconds across the displayed five seconds). The rate across the first three beats is about 125 beats/min; the average over the full ten seconds is about 121 beats/min. In lead II, positive P waves of the same shape precede each QRS, with a 1:1 relationship. PR is approximately 120–140 ms, based on the existing manual visual estimate, with uncertainty of ±10–20 ms. The waveform alone does not establish the cause of tachycardia. [Q2]

This is an anonymized, publicly available real recording, not a synthetic waveform. This learning resource does not provide symptoms or treatment history. [Q2]

Do not infer a disease or its cause from the rate alone. G2’s section on sick sinus syndrome emphasizes the relationship between bradycardia and symptoms. Sick sinus syndrome involves problems with sinus node function; a recording of bradycardia alone cannot establish the diagnosis. [G2: Chapter 2, section 1.1.1, p.32; section 1.1.4, p.34]

Features of atrial fibrillation (AF)

AF stands for atrial fibrillation. Clues include the absence of clearly repeating P waves and irregular RR intervals. Irregular RR intervals alone are not enough to identify AF. [G2: Chapter 2, section 2.1; Table 15, p.38]

Figure 8. Original educational illustration of two AF features: no clear, repeating P waves and irregular RR intervals. Not a patient ECG. Not for diagnosis.

This five-second figure is a synthetic waveform for learning these features. Table 15 in G2 addresses ECG documentation and diagnostic conditions. This article does not teach clinical diagnosis of AF from a short schematic or an alarm display alone.

Figure 8a. q07, 0–5 seconds: a real atrial fibrillation waveform. PTB-XL v1.0.3, record 04117. Wagner et al.; PhysioNet; CC BY 4.0. 25 mm/s; 10 mm/mV. Japanese title and footer cropped; waveform area preserved.

Check a real recording: atrial fibrillation. Observations of the full ten-second recording in the existing learning material describe irregular RR intervals of approximately 0.35–0.74 seconds, no repeating P waves of a consistent shape in II or V1, and no identifiable regular sawtooth atrial waves. Within the displayed 0–5 seconds, intervals with both R waves visible are approximately 0.36–0.51 seconds. Do not confuse measurements from the full ten seconds with the five-second excerpt. This short recording does not establish the duration or clinical type of AF. [Q7]

This is an anonymized, publicly available real recording, not a synthetic waveform. This learning resource does not provide symptoms or treatment history. [Q7]

First-degree atrioventricular block

Atrioventricular refers to the atria and ventricles. In first-degree atrioventricular (AV) block, PR is prolonged while the 1:1 relationship between P and QRS is maintained. PR longer than 0.2 seconds is classified as first-degree AV block in G2. The schematic uses PR of 0.26 seconds. This explains a classification; it does not assess the urgency of a response. [G2: Chapter 2, section 1.2.2, p.34]

Figure 9. Original educational illustration of first-degree AV block, with PR set to 0.26 seconds. Notice how far P precedes QRS. Not a patient ECG. Not for diagnosis.

Figure 9a. q03, 0–5 seconds: a real recording for examining AV conduction. PTB-XL v1.0.3, record 00191. Wagner et al.; PhysioNet; CC BY 4.0. 25 mm/s; 10 mm/mV. Japanese title and footer cropped; waveform area preserved.

Check a real recording: first-degree AV block. Review of the original signal during quality assurance found PR of approximately 330–350 ms across the first three beats. P and QRS had a 1:1 relationship throughout the ten seconds examined, with no dropped beats. Only two beats have a QRS within the displayed 0–5 seconds: the third QRS begins at about 5.42 seconds, outside the excerpt. PR in the fourth beat appears longer, at approximately 390 ms; this beat is also outside the displayed 0–5 seconds. These PR values are manual visual estimates, with uncertainty of approximately ±10–20 ms. [Q3]

Bradycardia and high left ventricular voltage are also present, so learning from this example is limited to AV conduction. It is not an example for judging whether the entire recording is normal or whether urgent action is needed. [Q3]

This is an anonymized, publicly available real recording, not a synthetic waveform. This learning resource does not provide symptoms or treatment history. [Q3]

Step 4: limit your conclusions from a real recording

The following q01 example comes from existing learning material using an anonymized, publicly available real recording. It is not a synthetic waveform. It is not a clinical case of an alarm event, and no symptoms or treatment history are assigned to it. [Q1]

Quick question 2: what is the underlying rhythm in this recording? Examine all twelve leads in both the 0–5-second and 5–10-second images. [Q1: question and options inherited from the existing q01 material]

  • A: Sinus rhythm in the normal rate range (60–100 beats/min)
  • B: Sinus bradycardia (below 60 beats/min)
  • C: Atrial fibrillation
  • D: Complete AV block

Figure 10. q01, 0–5 seconds, all twelve leads. An anonymized public real recording. PTB-XL v1.0.3, record 00002. Wagner et al.; PhysioNet; CC BY 4.0. 25 mm/s; 10 mm/mV. Japanese title and footer cropped; waveform area preserved.

Figure 11. q01, 5–10 seconds: the continuation of the same recording. PTB-XL v1.0.3, record 00002. Wagner et al.; PhysioNet; CC BY 4.0. 25 mm/s; 10 mm/mV. Japanese title and footer cropped; waveform area preserved.

The recording scale is 25 mm/s and 10 mm/mV. Calibration pulses within the grids of I and V1 are 0.2 seconds wide and 1 mV high. [Q1]

Answer: B. In lead II, positive P waves of the same shape precede the QRS complexes, with a 1:1 relationship. Across all seven beats, RR intervals are approximately 1.16–1.37 seconds; the mean of approximately 1.27 seconds gives a rate of about 47 beats/min. The RR intervals are not constant. [Q1]

Considering only the first three beats gives RR intervals of approximately 1.30–1.37 seconds and a rate of about 45 beats/min. The estimate changes with the section examined. Manual visual estimates of PR across the first three beats are approximately 150–180 ms (milliseconds), with uncertainty of approximately ±10–20 ms. These are not precise measurements of every beat. [Q1]

The rate helps distinguish B from A, repeating P waves help distinguish it from C, and the P-to-QRS relationship helps distinguish it from D. “Below 60 beats/min” is the learning category used in this existing exercise, not a threshold for starting treatment. JCS 2022 (G2) and the ACC/AHA/HRS 2018 guideline on bradycardia define sinus bradycardia as a sinus rate of approximately 50 beats/min. [Q1]

The recording does not tell us the symptoms, blood pressure, circulatory state or clinical course before and after the event. Document separate statements such as “RR intervals are not constant,” “P precedes QRS” and “no information on symptoms or circulation.” Dataset annotations and a confirmed clinical diagnosis are different things. [Q1; G2: p.32]

Step 5: report observations, the course of events and questions

In discussing the diagnosis of sick sinus syndrome, G2 covers symptom frequency and duration, the circumstances and time of onset, and medication history. The following is an editorial reporting suggestion informed by that approach. It is not a society-prescribed format for all alarms. [G2: Chapter 2, section 1.1.4 a, pp.32–33]

FieldWhat to record briefly
Current conditionTime of observation / what the patient reports / responsiveness, breathing and circulation / measurements and their conditions
Display and findingsAlarm label exactly as displayed / P-to-QRS relationship / changes in RR / what you cannot interpret
Before and after onsetStart and end times / changes before, during and after / periods without a recording
Actions and questionsActions taken and when / instructions received / what you need to discuss now

Follow institutional procedures for recording conditions, saving waveforms, electrode care and alarm settings. Not assuming “it is only noise, so it is safe” simply because there was movement is an editorial observation precaution in this article.

Distinguish the roles of monitor ECGs and 12-lead ECGs. [G2: Chapter 1, section 3, p.12; section 3.2, p.14] Confirm further assessment with the responsible clinician.

Quick question 3: you know the alarm label, but have not yet checked the patient. Is the alarm label alone a complete report?

Answer: no. The patient’s condition, the course of events and unconfirmed information also matter. Prioritize calling for help when needed; do not wait to finish a note. This question reviews how the article organizes information.

Do not transfer patient records to a personal smartphone or an external service to make learning materials. Handle work records within the environment specified by your institution.

Sources and attribution

G2: Japanese Circulation Society and Japanese Heart Rhythm Society. 2022 Guideline on Diagnosis and Risk Assessment of Arrhythmia (2022; Japanese-language guideline). https://www.j-circ.or.jp/cms/wp-content/uploads/2022/03/JCS2022_Takase.pdf

Relevant printed pages: Chapter 1, section 3, p.12 and section 3.2, p.14 (the role of ECGs and monitoring); Chapter 2, section 1.1.1, p.32, section 1.1.4 a, pp.32–33 and section 1.1.4, p.34 (symptoms and history in sick sinus syndrome); section 1.2.2, p.34 (classification of AV block); section 2.1, pp.37–38 and Table 15, p.38 (AF). This source is not used to specify drawing scales, alarm management or nursing documentation formats.

E1: Supplementary reference for basic ECG terms: ECG terminology (Japanese-language page). The schematics and calculations are educational examples created for this article.

Q1: Existing learning exercise q01, using PTB-XL v1.0.3, record 00002. The question, options, correct answer and measurement explanations were inherited from the existing article and condensed. The Japanese article copied the two existing final images without alteration. For this English edition, the Japanese title and footer have been cropped away; the waveform area, lead labels and calibration pulses are preserved without redrawing. English captions provide the recording interval, scale and attribution.

  • Dataset: Wagner, P., Strodthoff, N., Bousseljot, R., Samek, W., & Schaeffter, T. (2022). PTB-XL, a large publicly available electrocardiography dataset (version 1.0.3). PhysioNet. RRID:SCR_007345. https://doi.org/10.13026/kfzx-aw45
  • Original paper: Wagner, P., Strodthoff, N., Bousseljot, R.-D., Kreiseler, D., Lunze, F.I., Samek, W., Schaeffter, T. (2020). PTB-XL: A Large Publicly Available ECG Dataset. Scientific Data. https://doi.org/10.1038/s41597-020-0495-6
  • PhysioNet citation inherited from the existing article: Pollard, T., Moody, B. E., Lehman, L., Gow, B., Fernandes, C., Xie, C., Johnson, A., Mark, R. G., & Heldt, T. (2026). PhysioNet as a global platform for biomedical research. Nature Health. https://doi.org/10.1038/s44360-026-00096-z . https://pmc.ncbi.nlm.nih.gov/articles/PMC13641116/
  • Source: https://physionet.org/content/ptb-xl/1.0.3/ . License: CC BY 4.0, https://creativecommons.org/licenses/by/4.0/ .
  • Inherited modification statement: waveform values were preserved while the data were redrawn for education, with excerpts, measurement lines, captions and reference calibration pulses added. The calibration pulse positions and header were subsequently organized. The Japanese article’s copies made no further image changes; the English cropping described above removes the Japanese margins. This does not imply endorsement by the original authors or PhysioNet.

Q2: PTB-XL v1.0.3, record 00108, existing exercise q02 (sinus tachycardia). The original preparation used the measurement record `q02-measurements.json`. Independent remeasurement during quality assurance found RR intervals of 484 and 482 ms across the first three beats, giving approximately 125 beats/min for those beats (about 121 beats/min on average over the full ten seconds). PR of approximately 120–140 ms is a manual visual estimate.

Q3: PTB-XL v1.0.3, record 00191, existing exercise q03 (first-degree AV block). The original preparation used `q03-measurements.json`. Quality assurance found PR of approximately 330–350 ms across the first three beats and about 390 ms in the fourth. The third and fourth beats are outside the displayed 0–5 seconds. P and QRS have a 1:1 relationship throughout the ten seconds examined, with no dropped beats. The existing limitation is retained: bradycardia and high left ventricular voltage are also present; learning is restricted to AV conduction.

Q7: PTB-XL v1.0.3, record 04117, existing exercise q07 (atrial fibrillation). Measurements are based on the preparation record `q07-measurements.json`. RR of 352–742 ms over the full ten seconds and the existing visual findings in II and V1 are inherited. RR of 358–514 ms within the displayed 0–5 seconds was checked against the R-wave times in that JSON record.

For Q2, Q3 and Q7, the dataset authors (Wagner et al.), original paper and PhysioNet citation are the same as for Q1 above. Source: https://physionet.org/content/ptb-xl/1.0.3/ ; dataset DOI: https://doi.org/10.13026/kfzx-aw45 . CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). According to the provenance supplied for the Japanese article, these were educational redrawings and 0–5-second PNG excerpts from `production_ja7`. In that article’s quality-assurance revision, the old header calibration pulse and text were removed, and calibration pulses 0.2 seconds wide and 1 mV high were placed inside the grids of I and V1. Waveforms, lead labels and existing measurement lines were retained. This English edition crops away the Japanese title and footer, preserving the waveform area without redrawing, and supplies English captions. Neither the original authors nor PhysioNet endorse this material. These are public real recordings, not synthetic waveforms; symptoms and treatment history are not provided here.

The original article was prepared from the images and measurement JSON files. Independent quality assurance on November 9, 2026 then remeasured RR intervals and heart rates from the original signals and visually checked PR intervals. The Japanese revision reflected those findings. Direct comparison with the original exercise wording and copy source had not been performed. The scope and timing of those checks are recorded in the original preparation work log (WORKLOG). These statements describe the Japanese source’s review history, not a new verification of the signals for this translation.

The schematics and organizing diagrams in Figures 1–9 (excluding 7a, 8a and 9a) and the reporting table are original illustrations and editorial suggestions for this article. They do not trace third-party figures or tables. No images or text from third-party teaching materials were used. This is a public learning resource, but it has not undergone medical supervision.

Continue learning

Arrhythmias: learning guide

Explore all five cardiology topics